![]() Configure the Panel Manager selections as follows: Use the SIMATIC Software screen on the top of this page as reference. The C-more Panel Manager is shown above with the Siemens Ethernet S7-300 driver selected. From the Panel Manager window click on the DEV001 selection on the tree to the left to open the Device Setup screen of the Panel Manager window shown below.įrom the PLC Protocol field, click on the down arrow and select the Siemens S7-300 (Ethernet : ISO over TCP/IP) selection.Īll of the following settings must be set the same as the settings in Panel Manager in the C-more Programming Software. The drop-down menu shown below opens.įrom the Setup drop-down menu, select the Panel Manager selection. To access the Panel Manager from the C-more Programming Software, from the Main Menu select Setup. Be sure that the Subnet Mask shown matches the Subnet Mask of the C-more Panel. This is the IP Address to enter in the C-more Programming Software Panel Manager setup window. This window displays the IP Address and Subnet Mask settings for the PLC.Click on the Parameters Tab to select it.When selected, the Properties window shown below will open. Click on the Properties button to see more details on the IP Configuration. ![]() Note: If using a communications module, use the IP Address of the communications module in place of the PLC IP Address. The current PLC IP Address will be displayed on this location.Make sure the General Tab is selected to see the details shown above.This will open the Properties - PN-IO window shown below. Both the Rack Number and Slot Number are necessary configuration parameters for the C-more Programming Software Panel Manager setup. For the example shown above the Slot Number is 2. ![]() For the sample shown above, this Number is shown in parenthesis next to the text that says UR. Note the Rack Number of the device you are trying to connect to. ![]() When Hardware is selected, the HW Config (Hardware Configuration) window shown below will open. From the SIMATIC Manager window, select the Hardware option located on the right side pane and indicated below. To do this, open the SIMATIC Manager Software and project. To Configure the PLC to communicate with the C-more Panel, you will first need to find the Port Settings for your Siemens PLC. The C-more panel is the master when communicating with a Siemens PLC. The following information applies only to the Siemens Ethernet ISO over TCP/IP (S7-300) PLC compatible with C-more Panels. Siemens Ethernet ISO over TCP/IP (S7-300/400) Setup ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |